Disk Replacement

Introduction

If you notice that one of your hard drive is failing or that our system notifies you by email that your server is experiencing a hard drive failure, you should take action as soon as possible to address the issue.

This document will guide you for the replacement of your failing hard disk.

Backup

Before doing anything, it is really important to performs your backups. The sole purpose of a RAID (except RAID0) is to protect data against hard disk failures. Once a disk is failing, all your data depends on the health of the remaining disk.

It is improbable that two drives fails at the same time, but it is not impossible. By all means, implement an adequate backup strategy.

If you do not confirm that you have made your backup before asking for a disk replacement, you must state that you are aware of the risks and that you accept full responsibility.

Find defective disk(s)

Whether you have found the failure by yourself or if our system notified you, it is good practice to check the health of all hard disks.

The reason is that if we have two failing disks in a RAID array, we will start by replacing the disk with the higher error count.

Software RAID

Once you have found the device path of you disks, you can tests them using smartctl like so:

smartctl -a /dev/sdX

Note

Don’t forget to replace /dev/sdX for the actual device path of your disk.

Hardware RAID

Once you have found the device path of you disks, you can tests them using smartctl like so:

smartctl -d megaraid,N -a /dev/sdX
N: The drive’s Device ID
X: The RAID’s Device (/dev/sda = 1st RAID, /dev/sdb = 2nd RAID, etc.)

Note

Don’t forget to replace /dev/sdX for the actual device path of your disk.

Requesting a disk replacement

To request a disk replacement, simply open a Support Ticket.

To accelerate the process, please provide the following informations:

  1. A date and time at which we should perform the replacement (you must plan for a small down time, but replacements can be scheduled 24/24-7/7).
  2. A confirmation that either you have made your backup or that you take full responsibility for any data loss
  3. The serial number of the hard disk we must change
[1] If for some reasons it is not possible to retreive the Serial Number of the failing hard disk, please specify it in the ticket and provide the Serial Numbers of all other disks.

After the replacement

If you have Hardware RAID, the RAID will re-sync itself. Please note that the re-sync process can take some time and affect the read/write performances of your disks.

If you have Software RAID, then you will have to rebuild your RAID array.

  • 30 Users Found This Useful
Was this answer helpful?

Related Articles

Network IP Aliasing

Introduction IP aliasing is a special configuration of your dedicated server network, which...

Network Bridging

Introduction Bridged networking can be used to configure your Virtual Machines. Some tweaking...

Network Configuration

Introduction The network allows two configuration modes for public networking, Bridging and IP...